Isolated serial converter: we make your protocols talk.

The legacy PLC speaks RS-232. The new drive speaks RS-485. Your laptop only has USB. The LRI-CON line is the industrial bridge between them — isolated, protected, fully documented.

Galvanic isolation 600W TVS protection Auto-baud Up to 1200 m
LRI-CON-7562U isolated USB to RS-232/RS-422/RS-485/TTL converter

A converter is not an accessory. It's a critical link.

When the converter fails, the whole communication goes down — and production with it. The LRI-CON line was born from LRI engineering to be the link that doesn't break: real isolation, surge protection and documentation no generic import offers.

Real isolation and protection

Galvanic isolation across the line, with 600W TVS protection on the 7562U and 7521U: the expensive equipment at the other end of the line stays safe from spikes, noise and potential differences.

Complete technical manuals

Every LRI-CON model ships with a detailed technical manual — pinout, wiring, topologies and troubleshooting. Request the PDF from LRI engineering by email or phone, no sign-up. (Currently in Portuguese; English versions coming.)

LRI engineering

A line developed under our global co-engineering model, specified and supported by people who have worked with industrial communication for decades. Meet our engineering →

Three models. Each solves a classic pain.

From the engineer's laptop to the star-topology bus: pick the right bridge for your scenario. And the line is expanding — new models coming soon.

LRI-CON-7562U — isolated USB to serial converter
USB → Serial

LRI-CON-7562U

Isolated module that turns 1 USB port into RS-232, RS-422, RS-485 or TTL. Powered by the USB port itself, with auto-baud and a virtual COM port on the PC. The field engineer's Swiss army knife.

1.5 kV (1500 VAC) isolation · 600W TVS · up to 1200 m · ≤100 mA over USB 5V

Manual in Portuguese: request it from LRI engineering at [email protected] or +55 51 2129-3000

LRI-CON-7520A — isolated industrial RS-232 to RS-485/RS-422 converter
RS-232 → RS-485/422

LRI-CON-7520A

Isolated industrial converter that gives legacy equipment a new life: turns the RS-232 port (DB9) into RS-485 or RS-422, jumper-selectable, DIN rail mounted.

1.5 kV (1500 VAC) isolation · DC 9–30V · up to 1200 m · DIN rail · detachable terminals

Manual in Portuguese: request it from LRI engineering at [email protected] or +55 51 2129-3000

LRI-CON-7521U — isolated splitter, 1 input to 4 RS-485 channels
1 input → 4× RS-485

LRI-CON-7521U

Isolated hub/splitter that converts 1 host port (RS-485, RS-232 or TTL) into 4 independent RS-485 channels — star topology without bus conflicts, with amplified, isolated signal.

Adaptive 300–230,400 bps · 600W TVS · up to 1200 m per port · DC 9–30V, ≤50 mA

Manual in Portuguese: request it from LRI engineering at [email protected] or +55 51 2129-3000

Compare all three in 30 seconds.

The essentials side by side. For pinout, wiring and full details, download each model's manual.

LRI-CON-7562U LRI-CON-7520A LRI-CON-7521U
Function Isolated USB → serial Isolated RS-232 → RS-485/422 Isolated splitter 1 → 4× RS-485
Input USB 2.0 RS-232 (female DB9) RS-485, RS-232 or TTL 3.3/5V
Output RS-232, RS-422, RS-485 or TTL RS-485 or RS-422 (jumper) 4× independent RS-485
Baud rate Auto-baud Auto-baud 600–115,200 bps Adaptive 300–230,400 bps
Isolation 1.5 kV (1500 VAC) 1.5 kV (1500 VAC) between ports Galvanic, independent channels
Protection 600W TVS Galvanic isolation 1.5 kV (1500 VAC) 600W TVS
Power From the USB port (5V, ≤100 mA) DC 9–30V DC 9–30V (≤50 mA @24V)
Distance (RS-485/422) Up to 1200 m Up to 1200 m Up to 1200 m per port
Operating temperature -40°C to +85°C Contact LRI engineering -40°C to +85°C
Relative humidity 10–90% RH, non-condensing Contact LRI engineering 10–90% RH, non-condensing
Manual Manual in Portuguese: request it from LRI engineering at [email protected] or +55 51 2129-3000 Manual in Portuguese: request it from LRI engineering at [email protected] or +55 51 2129-3000 Manual in Portuguese: request it from LRI engineering at [email protected] or +55 51 2129-3000

The 7520A LRI datasheet lists 9–30 VDC supply, up to 1200 m reach and 1.5 kV (1500 VAC) isolation between input and output. For operating temperature and relative humidity, LRI engineering confirms the exact value for your project — contact LRI engineering before you specify.

Which LRI-CON to pick.

Three simple questions solve 90% of cases. If your situation isn't here, it's quick: tell us what you have on one side and what you need on the other, and we'll point to the right model.

Only a USB port available?

Field laptop, bench PC or any equipment without a serial port: the 7562U turns the USB into an isolated RS-232, RS-422, RS-485 or TTL port, powered by the USB cable itself.

See the 7562U →

Legacy equipment with RS-232 only?

PLC, HMI or legacy instrument that only speaks RS-232, and the plant network is RS-485 or RS-422: the 7520A bridges it as a fixed DIN-rail install, with 1.5 kV (1500 VAC) isolation protecting both sides.

See the 7520A →

Need to distribute one bus to several points?

RS-485 network in a star topology, without bus conflicts: the 7521U splits 1 input (RS-485, RS-232 or TTL) into 4 independent, isolated and amplified RS-485 channels.

See the 7521U →

LRI engineering sizes it with you.

Tell us the source interface, the target interface and the cable distance — we confirm the right model before you buy, no guessing.

Talk to a specialist

Three classic pains, three direct solutions.

Commission in the field from a laptop

Your laptop has no serial port — and the drive, the power meter and the PLC only speak RS-485. With the 7562U in your pocket, any USB becomes an isolated industrial serial port.

Integrate legacy equipment

That trusty 15-year-old machine only has RS-232 — and the new network is RS-485. The 7520A on the DIN rail bridges them, with 1.5 kV (1500 VAC) isolation protecting both sides.

Distribute the bus in a star

RS-485 demands daisy-chain wiring, but your plant calls for a star topology. The 7521U splits 1 input into 4 isolated, amplified branches — no conflicts, no workarounds.

The line is growing: new LRI-CON models in development.

What people ask before buying a serial converter.

What is an RS-485 converter and what is it for?

It is the module that translates the electrical signal of one interface into another — for example, turning the RS-232 port of an old PC or PLC into the RS-485 bus used by drives, meters and PLCs on a Modbus network. Without it, the two devices simply cannot talk, even if wired to the same cable.

What is the difference between the USB converter (7562U) and the RS-232 converter (7520A)?

The 7562U starts from a USB port — built for the field engineer's laptop, which no longer has a serial port. The 7520A starts from an existing RS-232 port (DB9) on the panel or equipment, and is DIN-rail mounted for a permanent installation. Both reach the same place (RS-485 or RS-422), but solve different scenarios: one is for commissioning in the field, the other for a fixed install.

How do I know which LRI-CON model to choose?

It depends on the port you already have and what you need to reach. Only USB available → 7562U. Legacy equipment with RS-232 only and the new network is RS-485/422 → 7520A. Need to distribute one RS-485 bus to several devices without conflict → 7521U. See Which one to pick above or talk to a specialist telling us both ends of the connection.

Why does galvanic isolation matter in a serial converter?

Galvanic isolation electrically separates the converter's ports, so a potential difference, a surge or a grounding fault on one side of the line does not pass to the other. The whole LRI-CON line isolates at 1.5 kV (1500 VAC) — the 7562U and 7521U also add 600W TVS protection, which protects the expensive equipment on the other end, not just the converter.

What is the maximum RS-485 cable distance with LRI-CON?

Up to 1200 m per port on all three models — 7562U, 7520A and 7521U — assuming proper twisted-pair cable, line termination and the baud rate used (a higher baud rate reduces the practical distance).

Do the PDF manuals cover pinout and installation?

Yes, for pinout and wiring. The 7562U, 7520A and 7521U each have an LRI datasheet with pinout and wiring — the 7562U and 7521U datasheets also cover temperature, humidity and installation topology, and the 7520A's 9–30 VDC supply and up to 1200 m reach are confirmed; contact LRI engineering for its operating temperature and relative humidity. All three manuals are currently in Portuguese — request them from LRI engineering by email or phone, no sign-up.

Picked your model? Talk to us.

Tell us the model and quantity — we reply with price and lead time. All three models — 7562U, 7520A and 7521U — are already available at the LRI store, and the line keeps growing.

WhatsApp
+55 (51) 2129-3000

E-mail
[email protected]

Phone
+55 (51) 2129-3000 · +55 (11) 4020-2470

Store
www.lri.com.br

Chat on WhatsApp