Real isolation and protection
Galvanic isolation across the line, with 600W TVS protection on the 7562U and 7521U: the expensive equipment at the other end of the line stays safe from spikes, noise and potential differences.
The legacy PLC speaks RS-232. The new drive speaks RS-485. Your laptop only has USB. The LRI-CON line is the industrial bridge between them — isolated, protected, fully documented.
When the converter fails, the whole communication goes down — and production with it. The LRI-CON line was born from LRI engineering to be the link that doesn't break: real isolation, surge protection and documentation no generic import offers.
Galvanic isolation across the line, with 600W TVS protection on the 7562U and 7521U: the expensive equipment at the other end of the line stays safe from spikes, noise and potential differences.
Every LRI-CON model ships with a detailed technical manual — pinout, wiring, topologies and troubleshooting. Request the PDF from LRI engineering by email or phone, no sign-up. (Currently in Portuguese; English versions coming.)
A line developed under our global co-engineering model, specified and supported by people who have worked with industrial communication for decades. Meet our engineering →
From the engineer's laptop to the star-topology bus: pick the right bridge for your scenario. And the line is expanding — new models coming soon.

Isolated module that turns 1 USB port into RS-232, RS-422, RS-485 or TTL. Powered by the USB port itself, with auto-baud and a virtual COM port on the PC. The field engineer's Swiss army knife.

Isolated industrial converter that gives legacy equipment a new life: turns the RS-232 port (DB9) into RS-485 or RS-422, jumper-selectable, DIN rail mounted.

Isolated hub/splitter that converts 1 host port (RS-485, RS-232 or TTL) into 4 independent RS-485 channels — star topology without bus conflicts, with amplified, isolated signal.
The essentials side by side. For pinout, wiring and full details, download each model's manual.
| Function | Isolated USB → serial | Isolated RS-232 → RS-485/422 | Isolated splitter 1 → 4× RS-485 |
|---|---|---|---|
| Input | USB 2.0 | RS-232 (female DB9) | RS-485, RS-232 or TTL 3.3/5V |
| Output | RS-232, RS-422, RS-485 or TTL | RS-485 or RS-422 (jumper) | 4× independent RS-485 |
| Baud rate | Auto-baud | Auto-baud 600–115,200 bps | Adaptive 300–230,400 bps |
| Isolation | 1.5 kV (1500 VAC) | 1.5 kV (1500 VAC) between ports | Galvanic, independent channels |
| Protection | 600W TVS | Galvanic isolation 1.5 kV (1500 VAC) | 600W TVS |
| Power | From the USB port (5V, ≤100 mA) | DC 9–30V | DC 9–30V (≤50 mA @24V) |
| Distance (RS-485/422) | Up to 1200 m | Up to 1200 m | Up to 1200 m per port |
| Operating temperature | -40°C to +85°C | Contact LRI engineering | -40°C to +85°C |
| Relative humidity | 10–90% RH, non-condensing | Contact LRI engineering | 10–90% RH, non-condensing |
| Manual | Manual in Portuguese: request it from LRI engineering at [email protected] or +55 51 2129-3000 | Manual in Portuguese: request it from LRI engineering at [email protected] or +55 51 2129-3000 | Manual in Portuguese: request it from LRI engineering at [email protected] or +55 51 2129-3000 |
The 7520A LRI datasheet lists 9–30 VDC supply, up to 1200 m reach and 1.5 kV (1500 VAC) isolation between input and output. For operating temperature and relative humidity, LRI engineering confirms the exact value for your project — contact LRI engineering before you specify.
Three simple questions solve 90% of cases. If your situation isn't here, it's quick: tell us what you have on one side and what you need on the other, and we'll point to the right model.
Field laptop, bench PC or any equipment without a serial port: the 7562U turns the USB into an isolated RS-232, RS-422, RS-485 or TTL port, powered by the USB cable itself.
See the 7562U →PLC, HMI or legacy instrument that only speaks RS-232, and the plant network is RS-485 or RS-422: the 7520A bridges it as a fixed DIN-rail install, with 1.5 kV (1500 VAC) isolation protecting both sides.
See the 7520A →RS-485 network in a star topology, without bus conflicts: the 7521U splits 1 input (RS-485, RS-232 or TTL) into 4 independent, isolated and amplified RS-485 channels.
See the 7521U →Tell us the source interface, the target interface and the cable distance — we confirm the right model before you buy, no guessing.
Talk to a specialistYour laptop has no serial port — and the drive, the power meter and the PLC only speak RS-485. With the 7562U in your pocket, any USB becomes an isolated industrial serial port.
That trusty 15-year-old machine only has RS-232 — and the new network is RS-485. The 7520A on the DIN rail bridges them, with 1.5 kV (1500 VAC) isolation protecting both sides.
RS-485 demands daisy-chain wiring, but your plant calls for a star topology. The 7521U splits 1 input into 4 isolated, amplified branches — no conflicts, no workarounds.
The line is growing: new LRI-CON models in development.
It is the module that translates the electrical signal of one interface into another — for example, turning the RS-232 port of an old PC or PLC into the RS-485 bus used by drives, meters and PLCs on a Modbus network. Without it, the two devices simply cannot talk, even if wired to the same cable.
The 7562U starts from a USB port — built for the field engineer's laptop, which no longer has a serial port. The 7520A starts from an existing RS-232 port (DB9) on the panel or equipment, and is DIN-rail mounted for a permanent installation. Both reach the same place (RS-485 or RS-422), but solve different scenarios: one is for commissioning in the field, the other for a fixed install.
It depends on the port you already have and what you need to reach. Only USB available → 7562U. Legacy equipment with RS-232 only and the new network is RS-485/422 → 7520A. Need to distribute one RS-485 bus to several devices without conflict → 7521U. See Which one to pick above or talk to a specialist telling us both ends of the connection.
Galvanic isolation electrically separates the converter's ports, so a potential difference, a surge or a grounding fault on one side of the line does not pass to the other. The whole LRI-CON line isolates at 1.5 kV (1500 VAC) — the 7562U and 7521U also add 600W TVS protection, which protects the expensive equipment on the other end, not just the converter.
Up to 1200 m per port on all three models — 7562U, 7520A and 7521U — assuming proper twisted-pair cable, line termination and the baud rate used (a higher baud rate reduces the practical distance).
Yes, for pinout and wiring. The 7562U, 7520A and 7521U each have an LRI datasheet with pinout and wiring — the 7562U and 7521U datasheets also cover temperature, humidity and installation topology, and the 7520A's 9–30 VDC supply and up to 1200 m reach are confirmed; contact LRI engineering for its operating temperature and relative humidity. All three manuals are currently in Portuguese — request them from LRI engineering by email or phone, no sign-up.
Tell us the model and quantity — we reply with price and lead time. All three models — 7562U, 7520A and 7521U — are already available at the LRI store, and the line keeps growing.